Description
UNIVERSAL MODEL # 3500FACV
175,000 – 350,000 BTU’S
AUTO IGNITION
MUST OPERATE FROM 2 OR MORE 100LB TANKS
HOSE LENGTH: 10FT
20 PSI REGULATOR
HEATING AREA FORMULA:
L X W X H X .133 X TEMPERATURE RISE (DIFFERENCE BETWEEN OUTSIDE TEMPERATURE & DESIRED INDOOR TEMPERATURE)
I.E. 20 DEGREES OUTSIDE – 40 DEGREES INSIDE = 20 DEGREE TEMPERATURE RISE
120 X 60 X 8 X .133 X 20 = 153,000 BTU’S NEEDED
Industrial forced air heater, with fully variable heat output for accurate temperature control.