Description
DESA INTERNATIONAL. MODEL RCP275.
275,000 BTU/HR.
PROPANE FUEL: PROPANE
CONSUMPTION: 3 GAL/HR OR 12.75 LB/HR.
REGULATOR OUTPUT SET TO 14 PSI.
WEIGHT 15 lbs.
18-1/2″L X 16″W X 23-1/8″H.
VENTILATION REQUIRES FRESH AIR OPENING OF 8.2 SQ FEET.
A 100LB PROPANE TANK WILL LAST APPOX. 8 HOURS
HEATING AREA FORMULA:
L X W X H X .133 X TEMPERATURE RISE (DIFF BTW OUTSIDE TEMPERATURE & DESIRED INDOOR TEMPERATURE)
I.E. 20 DEGREES OUTSIDE – 40 DEGREES INSIDE = 20 DEGREE TEMPERATURE RISE
120 X 60 X 8 X .133 X 20 = 153,000 BTU’S NEEDED